HP Smart Array P212 Æß¿þ¾î ¹× driver ¾÷µ¥ÀÌÆ®

   Á¶È¸ 21748   Ãßõ 0    

http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareIndex.jsp?la¡¦ (650)

2월 191068;1088;/196; 6156;웨Ǻ12; 0143; 드라1060;버 업데1060;트 .104;었내요..
아마도 Smart Array 1228;품군 모.160; 업데1060;트 .104;었1012;,161;니다..
모.160; 업데1060;트 해보아요~

아참 1200;lj16; 윈도우 서버 2012 사용1473;1077;니다. 다른 OSlj16; 업데1060;트.104;었lj16;1648; 모르,192;내요.


6156;웨Ǻ12;lj16; 6.00 1004;/196; 업데1060;트 됐습니다..1월 1473;순에 5.70(b)/196; 업뎃했lj16;데 한번 성능향상1060; 1080;나 봐야,192;내요..

¸Å´ÏÁö¸ÕÆ® ¼ÒÇÁÆ®¿þ¾îµµ ¾÷±×·¹À̵åµÆ³»¿ä...
ȸ¿øK 2013-03
Problems Fixed:
The following problems are addressed in version 6.00 of Online ROM Flash Component for Linux - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812:

On rare occasions during power-up of an HP DS2200sb the expander backplane would be unresponsive. When the expander backplane was unresponsive, the attached Smart Array Controller was not allowed to discover drives that were attached.
On an HP P812 controller, executing several sequential Write operations to more than 75 hard drives would result in a controller lockup.
Modified the FBWC module code to improve the training of the DDR2 DIMMs in order to prevent the rare occasions when 1783 POST error messages displays followed by an unresponsive controller.
Protection has been added to prevent potential Smart Array controller hangs under rare conditions when hot-adding hard drives.
When running in a Solaris environment, Smart Array firmware version 6.00 works around an issue where the driver would not handle asynchronous events from the Smart Array controller properly.
An interaction issue occurred between the Smart Array Controller and HP SAS Expander card in which the Hard Drives attached to the HP SAS Expander were not being discovered occasionally upon boot up or hot plug.
On rare occasions, the Smart Array controller would reset the same SATA drive several times when a PHY is stuck longer than four seconds.
The Smart Array P711m and P712m would report false link errors.
The Open Connection timeout was reduced to 900 microseconds so that SAS connections terminate gracefully and data transfer stalls are prevented.
The Smart Array controller would not connect to hard drives within 20ms under heavy stress.
Upon power up, a Post message will now be displayed to the user to indicate that a cache module is needed for the P711m controller.
When running heavy I/O in RAID 5, while an HP P410 controller was connected to more than 17 SAS drives in an HP DL180 G6 server with a 25SFF backplane, a lockup issue (error code 0xAB or 0xEA) could occur.
During heavy I/O when the HP P711m controller is connected to a HP P2000sa G3 MSA Array System via a HP 6Gb SAS Switch, a lockup issue (error code 0x15) could occur.
After a system with (2) or more empty SAS storage boxes, Box 1, 2, 3 ¡¦, attached to an HP SAS Expander card is powered up and then a drive is hot plugged into Box 2 or above, ACU and ORCA would incorrectly display the drive in Box 1.
ÁøÂ¥ ¹«½ÄÇÑ Áú¹®Àä P410À» »ç¿ëÇÏ°í ÀÖ½À´Ï´Ù..

Æß¿þ¾î ¾÷±×·¹À̵带 ¾î¶»°Ô Çؾߵdzª¿ä?? ÀоîºÁµµ ÀÌÇØ°¡ À߾ȵdz׿ä...


Á¦¸ñPage 10/51
2014-08   47789   witbox
2014-09   22500   ¹«¸ð´Ï
2014-10   62709   ADUS
2014-11   84375   ³ª¿ì¸¶Å©
2015-01   47212   ÆÄ¿À¸®
2015-03   73315   Àü¼³¼ÓÀǹ̡¦
2015-05   50808   ¸Ö·çÇÏÁö
2015-07   60433   º°µéÀǼӻèÀÓ
2015-08   28355   Ãʺ¸IT
2015-10   20290   ºÒ°úµ¿±âµ¿
2015-11   11498   ±èÇö¸°
2015-12   13641   µð½ºÅ丮
2016-01   14628   karil
2016-03   16087   PiPPuuP
2016-07   14081   ¾ËÆÎ
2016-10   8150   ½ÅÇöÁØ
2017-03   21462   freefree
2017-06   10120   ´À³¦
2017-11   11267   ¸®µë¾Ø¹öÅÍ
2018-01   15729   ±ÔÇö